  "record": "ZENIT-FEROS-CONCEPT-R6",
  "reviewed_on": "2026-11-26",
  "status": "Concept baseline; physical design and qualification pending",
  "crew_target": 48,
  "crew_target_status": "Owner-selected complement. Accommodation capacity and endurance remain unqualified.",
  "sleeping_quarters": true,
  "planned_berths": 48,
  "fusion_core_count": 1,
  "core_scale": "Smaller than the Earth powerplant core is a design goal. Physical dimensions, mass and output remain unrecorded.",
  "summary": "Feros R6 retains 48 crew, three decks, one fusion core, twin propellers and the 12,000 kW total shaft target. It adds a declared normal/emergency load schedule, generator charging headroom and a steady-state heat balance to the R5 resource and reserve calculations.",
  "operating_brief": [
    "Current design targets: 48 crew and 48 planned berths on three decks, a 14-day normal mission and a further 72-hour emergency-support period. Normal and emergency consumables are budgeted separately, including conditions at the end of the normal mission. These provisional durations remain subject to the rescue plan.",
    "Propulsion retains a 12,000 kW total shaft target, or 6,000 kW per propeller for an equal split. Independent shaft control and isolation are required. Two propellers do not provide two independent energy sources.",
    "One fusion heat source supplies the closed freshwater steam circuit. Separate propulsion turbines and a service turbine-generator share that source, steam supply, feedwater and heat-rejection dependencies. The condenser returns working water. Steam or seawater never enters the cabin-air circuit.",
    "The normal electrical path is service turbine-generator, Power Fuse Chamber, then SERAT-F. Service electricity is additional to shaft output. The service generator must supply required services with propulsion stopped; this is a requirement to size and demonstrate.",
    "Startup power and protected emergency power are separate functions. The emergency bank is reserved for essential occupied-cabin services, local protection, communications, necessary cooling and recovery functions. Startup and routine charging must not consume its protected reserve. Physical segregation, transfer hardware, delivered power and usable energy are not yet demonstrated.",
    "The protected emergency source must remain usable after loss of the common reactor/steam/service-generator chain and after the selected single-fault cases. Charging is limited by available service-generation headroom. No credit is taken for continuous charging during loss of generation.",
    "Main breathing support retains regulated stored oxygen, CO2 scrubbing, circulation, heat and humidity control. A separately protected emergency oxygen, CO2-removal and breathing provision is required for all 48 crew. Electrical delivery alone does not establish breathable atmosphere, scrubber capacity or occupied endurance.",
    "R5 carries the existing project metabolic reference into a 48-crew inventory calculation. At the inherited average rates, oxygen consumption is 43.2 kg/day and CO2 production is 51.84 kg/day. Reference emergency demand over 72 hours is 129.6 kg O2 and 155.52 kg CO2 to capture. These are calculated consumption totals without installation, activity, leakage or margin allowances.",
    "Residual heat in the core, coolant and machinery must be removed after shutdown. A closed clean-water cooling boundary transfers heat through isolated heat exchangers to a seawater heat sink. Loss of main pumping must not remove every means of essential shutdown cooling.",
    "Pressure-hull strength, hydrostatic pressure, displacement, trim, flood boundaries, reserve buoyancy and two independent surfacing means require naval-architecture calculations and evidence. At least one surfacing means must not depend on main electrical power. Aurora Shield and mCMC receive no pressure-hull, buoyancy, emergency-air or cooling credit.",
    "NEXUS-F coordinates information and proposed load priorities. GENI monitors quality and discrepancies. Local protection and AXIOM retain physical permission and isolation. A fresh display or cleared example event cannot authorize restart; ZSA acceptance requires vessel-specific evidence.",
    "The cutaway has arbitrary display coordinates. Representative furnishings and equipment markers do not establish scale, installed accommodation, fire boundaries, shielding, maintenance clearance or escape routes."
  ],
  "functions": [
    {
      "id": "fusion",
      "title": "Single fusion core and steam cycle",
      "description": "One proposed plasma fusion core heats a closed freshwater steam circuit. Separate propulsion and service turbines share its steam, feedwater and heat-rejection dependencies. Core thermal output, confinement, radiation protection, fuel handling and residual-heat removal require vessel-specific design evidence.",
      "flow_label": "Conceptual steam-cycle functions",
      "flow": [
        "Fusion heat",
        "Freshwater steam",
        "Turbine duties",
        "Condensation and feedwater return"
      ]
    },
    {
      "id": "generator",
      "title": "Service turbine-generator",
      "description": "A service turbine-generator draws from the common steam system and feeds the Power Fuse Chamber and SERAT-F. It must support normal services with the propellers stopped. A separate machine is not an independent emergency source. Continuous output, peaks and charging headroom remain to be sized.",
      "flow_label": "Conceptual service-electricity path",
      "flow": [
        "Service turbine-generator",
        "Power Fuse Chamber",
        "SERAT-F",
        "Cabin and equipment services"
      ]
    },
    {
      "id": "fuse",
      "title": "Power Fuse Chamber",
      "description": "The Power Fuse Chamber is the proposed normal electrical protection and conditioning boundary. Fault isolation and emergency transfer need independent local protection. A failure here must not remove every essential emergency feed. No hardware rating is assigned."
    },
    {
      "id": "serat",
      "title": "SERAT-F",
      "description": "SERAT-F accounts separately for shaft power, service electricity, stored energy and heat. It prioritizes essential crew, protection, cooling and recovery loads ahead of research and shield experiments. Charging can use only verified generation headroom."
    },
    {
      "id": "air",
      "title": "Breathing air and cabin conditioning",
      "description": "Regulated stored oxygen, soda-lime CO2 removal, circulation and heat/humidity control serve the 48-crew target. Local and independent backup O2, CO2, pressure, temperature and humidity instruments are required. A separate emergency provision must remain available after a main-system fault. Gas inventory, airflow, scrubber breakthrough and heat rejection remain unmeasured.",
      "flow_label": "Conceptual recirculating cabin-air functions",
      "flow": [
        "Occupied spaces",
        "CO2 removal",
        "Air conditioning and circulation",
        "Return to occupied spaces"
      ]
    },
    {
      "id": "mcmc",
      "title": "mCMC and GENI",
      "description": "mCMC supplies the proposed magnetic reference and GENI monitors field coordination and discrepancies. Neither creates energy or replaces the fusion core, pressure hull, buoyancy control or local protection. Hull-coil insulation, electrical faults and magnetic interaction remain open."
    },
    {
      "id": "telemetry",
      "title": "NEXUS-F and TSC",
      "description": "NEXUS-F is supervisory. Time, source, units, freshness and independent reference checks accompany observations. TSC is an acoustic-message concept; surface and underwater communications need separate verified recovery paths. Loss of fiber must not disable local protection or crew instruments."
    },
    {
      "id": "battery",
      "title": "Startup and emergency electricity",
      "description": "A startup source and a separately protected emergency bank are distinct R4 requirements. The emergency bank is reserved for essential loads for the provisional 72-hour target, subject to delivered-power and usable-energy sizing. No charging or reserve replenishment is assumed during loss of generation."
    },
    {
      "id": "shield",
      "title": "Aurora Shield research",
      "description": "Aurora Shield retains five layers across five sectors: 25 regions. Experiments are shed ahead of essential services and receive no protection, acoustic, pressure-hull, surfacing or life-support credit. Physical effects and coil isolation remain unvalidated."
    },
    {
      "id": "cooling",
      "title": "Cooling and heat rejection",
      "description": "Separate clean coolant from seawater with monitored heat-exchanger boundaries. Account for the propulsion condenser, service cycle, occupied cabin and residual heat after shutdown. Loss of a pump, seawater path or main bus requires a protected response; capacities and redundancy remain to be established."
    },
    {
      "id": "hull",
      "title": "Pressure hull, trim and recovery",
      "description": "Steel pressure-hull and titanium coil concepts require material and compatibility review. Establish depth, displacement, stability, flood detection, compartment isolation, bilge control, entanglement recovery and independent surfacing means before assigning a capability."
    },
    {
      "id": "crew-safety",
      "title": "Crew protection and habitability",
      "description": "Separate machinery, batteries, oxygen storage and occupied spaces against common fire and flooding faults. Provide escape access, smoke control, sanitation, medical provisions, food and potable-water budgets for 48 crew and the selected duration. The artwork is not a compartment or evacuation plan."
    }
  ],
  "safety_scope": "NEXUS-F is supervisory; GENI reports quality and discrepancies. AXIOM and independent local protection retain physical permission and isolation. ZSA owns independent acceptance. R6 reconciles the concept and software; it does not certify a constructed vessel.",
  "source_note": "Owner-selected 48 crew, three decks and 12,000 kW shaft target; prior power-cycle and air selections in ZENIT_Feros_Airos_Trell_Study.xlsx v9. On 26 November the owner delegated remaining concept decisions. R4 selects provisional 14-day normal and additional 72-hour emergency targets. These are requirements, not installed ratings or proven endurance. R5 derives 0.90 kg O2/person/day and 1.08 kg CO2/person/day from the workbook v10 historical 150-person, 135 kg O2/day and 162 kg CO2/day example. These existing project assumptions are retained as reference arithmetic, without claiming validated metabolic demand, equipment ratings or storage margins. R6 reconciles workbook v11 with the website and cutaway. It adds accounting equations using declared inputs; no new equipment rating, outside study or physical qualification is adopted.",
  "physical_validation": "Not demonstrated",
  "supersedes": "ZENIT-FEROS-CONCEPT-R5",
  "berth_status": "Accommodation target for the crew; representative furniture does not establish installed capacity or room dimensions.",
  "deck_count": 3,
  "propeller_count": 2,
  "shaft_power_target_kw": 12000,
  "equal_split_target_kw": 6000,
  "shaft_power_status": "Owner-proposed total shaft-power target. An equal split is an illustrative 6,000 kW per propeller, without demonstrated shaft output or thrust.",
  "reactor_thermal_output_mw": null,
  "service_electrical_demand_kw": null,
  "service_generator_output_kw": null,
  "hull_dimensions_m": null,
  "decks": [
    {
      "id": "crew",
      "label": "Upper deck",
      "title": "Upper deck \u00b7 daily operations",
      "description": "Navigation, watchkeeping and local safety indications occupy the upper deck, with NEXUS-F supervisory displays, communications and access to recovery and escape routes. Protection must remain available without the supervisory network."
    },
    {
      "id": "quarters",
      "label": "Middle deck",
      "title": "Middle deck \u00b7 living spaces",
      "description": "Target: 48 berths with mess, galley, food and water stores, sanitation and medical provision for the 14-day mission plus emergency period. Room dimensions, habitability, escape capacity and occupied volume require an accommodation plan."
    },
    {
      "id": "engineering",
      "label": "Lower deck",
      "title": "Lower deck \u00b7 systems and mechanics",
      "description": "The lower deck shows core, steam machinery, service generation, air equipment and electrical functions. R4 requires separated fire/flood zones for batteries, oxygen and machinery, service access and protected emergency paths. Current markers do not demonstrate this separation."
    }
  ],
  "viewer_summary": "Feros R6: 48 crew on three decks, one fusion core, twin propellers and separate startup and protected emergency power functions. The cutaway is an unscaled arrangement study.",
  "mission_days_target": 14,
  "mission_hours_target": 336,
  "emergency_hours_target": 72,
  "duration_status": "Provisional requirements: 14 days normal mission and an additional 72 hours of emergency support without resupply. Rescue time and operating area must be reconciled before qualification.",
  "power_dependencies": [
    {
      "path": "Normal propulsion",
      "chain": "Fusion heat \u2192 freshwater steam \u2192 propulsion turbines \u2192 independent shaft controls \u2192 twin propellers",
      "dependency": "Common reactor, steam, feedwater and cooling remain single-source dependencies."
    },
    {
      "path": "Normal electricity",
      "chain": "Common steam \u2192 service turbine-generator \u2192 Power Fuse Chamber \u2192 SERAT-F \u2192 loads",
      "dependency": "Propeller stop must not stop service generation. Reactor/steam loss can stop both branches."
    },
    {
      "path": "Protected emergency",
      "chain": "Separate protected emergency bank \u2192 locally protected essential distribution \u2192 essential loads",
      "dependency": "Independent of the failed normal source and supervisory network. Segregation and transfer performance require evidence."
    },
    {
      "path": "Shutdown cooling",
      "chain": "Stored machinery heat \u2192 protected cooling path \u2192 available heat sink",
      "dependency": "Required after shutdown. Emergency pumps and controls count in the essential electrical budget."
    }
  ],
  "operating_modes": [
    {
      "mode": "Alongside and startup",
      "requirements": "Verify local instruments, shore/startup source, coolant availability and protected emergency reserve. Account for startup energy separately.",
      "restriction": "Occupied startup requires working air support and an available recovery path."
    },
    {
      "mode": "Normal submerged",
      "requirements": "Verify normal generation, atmosphere, cooling, navigation, depth/trim and the remaining mission and emergency inventories.",
      "restriction": "Advance only within an established operating envelope; depth and speed ratings are open."
    },
    {
      "mode": "Propulsion stopped",
      "requirements": "Maintain service-generator operation, air, cooling, controls and trim while shaft demand is zero.",
      "restriction": "Do not equate zero shaft demand with zero reactor or service demand."
    },
    {
      "mode": "Source or cooling fault",
      "requirements": "Local protection isolates the fault, sheds experiments and preserves essential air, cooling, indications and recovery supply.",
      "restriction": "The shared steam chain provides no independent backup credit."
    },
    {
      "mode": "Emergency recovery",
      "requirements": "Use the protected reserve and independent air provision while following the established surfacing/rescue plan.",
      "restriction": "72 hours is a sizing target; energy, gas, thermal and recovery capacities must each support it."
    },
    {
      "mode": "Shutdown and restart hold",
      "requirements": "Maintain residual-heat removal and local monitoring. Record fault closure and reserve restoration.",
      "restriction": "Restart requires verified physical conditions and AXIOM permission; ZSA controls acceptance."
    }
  ],
  "requirements": [
    {
      "id": "F-01",
      "area": "Crew and accommodation",
      "requirement": "48 crew; 48 planned berths; three decks",
      "status": "Owner-selected target",
      "evidence_needed": "Scaled accommodation, habitability and evacuation plan."
    },
    {
      "id": "F-02",
      "area": "Mission and rescue",
      "requirement": "14 days normal + 72 hours emergency without resupply",
      "status": "Provisional target",
      "evidence_needed": "Operating area, rescue timeline and replenishment plan."
    },
    {
      "id": "F-03",
      "area": "Propulsion",
      "requirement": "12,000 kW total shaft target; two propellers",
      "status": "Owner-selected target",
      "evidence_needed": "Shaft, turbine, propeller, efficiency and hydrodynamic analysis; speed in knots remains open."
    },
    {
      "id": "F-04",
      "area": "Reactor and steam",
      "requirement": "One fusion source; two duty branches",
      "status": "Concept architecture",
      "evidence_needed": "Core/confinement, radiation/materials, fuel, pressure-system and heat-balance evidence."
    },
    {
      "id": "F-05",
      "area": "Service electricity",
      "requirement": "Independent of shaft rotation, dependent on steam",
      "status": "Load-accounting method completed; installed demand and output open",
      "evidence_needed": "Continuous and peak load list, generator output and charging headroom."
    },
    {
      "id": "F-06",
      "area": "Startup and emergency energy",
      "requirement": "Separate startup source and protected emergency bank",
      "status": "R4 requirement",
      "evidence_needed": "Delivered essential-bus power and usable energy after losses, aging and operating conditions."
    },
    {
      "id": "F-07",
      "area": "Breathing support",
      "requirement": "Main and protected emergency provision for 48",
      "status": "Reference demand calculated; equipment unqualified",
      "evidence_needed": "O2 inventory, CO2 uptake and breakthrough, airflow, humidity, pressure and local/backup instruments. R5 separates effective CO2 uptake from the hourly removal rate and from electrical power."
    },
    {
      "id": "F-08",
      "area": "Cooling",
      "requirement": "Normal and shutdown heat removal",
      "status": "Steady-state accounting completed; physical cooling open",
      "evidence_needed": "Heat loads, seawater envelope, exchanger/pump capacity and loss-of-main-power response."
    },
    {
      "id": "F-09",
      "area": "Hull and operating depth",
      "requirement": "Steel hull; material selection provisional",
      "status": "Open physical design",
      "evidence_needed": "Dimensions, mass, depth/pressure envelope, strength, fatigue and corrosion evidence."
    },
    {
      "id": "F-10",
      "area": "Buoyancy, flooding and surfacing",
      "requirement": "Independent recovery paths; one without main electric power",
      "status": "R4 requirement",
      "evidence_needed": "Displacement/trim/flood analyses and surfacing/recovery demonstration."
    },
    {
      "id": "F-11",
      "area": "Fire and separation",
      "requirement": "Protect occupied spaces and emergency paths",
      "status": "R4 requirement",
      "evidence_needed": "Compartment, oxygen/battery segregation, smoke, fire and escape assessment."
    },
    {
      "id": "F-12",
      "area": "Food, water and waste",
      "requirement": "Normal mission plus protected emergency inventory",
      "status": "Open sizing",
      "evidence_needed": "Per-person consumption, potable/process-water separation, storage and waste capacity."
    },
    {
      "id": "F-13",
      "area": "Navigation and communications",
      "requirement": "Local depth/trim indications and recovery communications",
      "status": "Concept requirement",
      "evidence_needed": "Independent instruments, submerged/surface links, position and emergency beacon evidence."
    },
    {
      "id": "F-14",
      "area": "Controls and observations",
      "requirement": "NEXUS-F supervisory; GENI quality; AXIOM/local protection",
      "status": "R4 authority boundary",
      "evidence_needed": "Fault containment, stale/missing data response and independent permission evidence."
    },
    {
      "id": "F-15",
      "area": "mCMC and Aurora Shield",
      "requirement": "Five layers; five sectors; 25 regions",
      "status": "Research only",
      "evidence_needed": "Coil insulation/interaction evidence. No essential-service or hull-protection credit."
    },
    {
      "id": "F-16",
      "area": "Independent acceptance",
      "requirement": "ZSA acceptance remains pending",
      "status": "Open qualification",
      "evidence_needed": "Vessel-specific hazard closure, configuration control and independently reviewed test evidence."
    }
  ],
  "space_to_earth": "Carry over explicit dependencies, reserve protection, load priorities, fresh-data checks, independent references and controlled restart. Feros uses water-side heat rejection and mechanical buoyancy; space radiators, MAGTRANS and shield effects do not provide submarine capabilities.",
  "energy_accounting": "Allocate steam heat separately to propulsion and service generation, including conversion and condenser losses. Service electric loads are additional to shaft output. At the whole-vessel boundary most onboard electrical consumption returns as heat: do not add it again as exported power. Battery charging is a load; discharge depletes stored energy. No efficiency, heat duty or reactor rating is assigned from the shaft target alone.",
  "life_support_basis": {
    "crew": 48,
    "normalDays": 14,
    "emergencyHours": 72,
    "oxygenKgPerPersonDay": 0.9,
    "co2KgPerPersonDay": 1.08,
    "waterLitresPerPersonDay": null,
    "foodKgPerPersonDay": null,
    "source": "ZENIT_Feros_Airos_Trell_Study.xlsx v10, Feros electrical demand, historical occupancy example: 150 people, 135 kg O2/day and 162 kg CO2/day.",
    "scope": "Existing project reference assumptions, rescaled to 48 crew. These totals exclude activity variation, leakage, unusable inventory and design margins. CO2 mass is the mass to capture, not the mass of soda lime. Oxygen mass does not establish tank volume. No regenerative/recharge credit is taken."
  },
  "improvement_steps": [
    {
      "step": "1. Essential electrical inventory",
      "completed": "R6 adds a normal/emergency grouped load schedule, separate charging demand and generator headroom, with blank and zero entries kept distinct. R5 reserve energy and peak-power checks remain separate.",
      "next_evidence": "Inventory every essential load, shared cooling and recovery duty once. Record running power, peak power and duration, source boundary and measurement conditions."
    },
    {
      "step": "2. Cycle heat accounting",
      "completed": "R6 calculates declared useful output, cycle heat input and conversion heat with a stated boundary. Zero shaft demand can be used to examine service-generation accounting with the propellers stopped.",
      "next_evidence": "Obtain a real thermodynamic design and measured conversion efficiency, auxiliary loads and heat-rejection allocation. Startup and post-shutdown heat removal are separate duties."
    },
    {
      "step": "3. Crew-specific atmosphere demand",
      "completed": "The older 150-person example is rescaled to 48 crew and split into normal, emergency and combined inventories. O2 inventory, effective CO2 uptake and hourly CO2 removal are checked separately.",
      "next_evidence": "Validate metabolic assumptions for the selected activity profile. Obtain usable oxygen inventory and CO2 uptake, breakthrough and rate evidence under the actual cabin conditions."
    },
    {
      "step": "4. Food and potable-water accounts",
      "completed": "Separate normal/emergency inventory calculations accept declared per-person daily rates. Unspecified rates remain unknown. Steam water and untreated condensate receive no potable-water credit.",
      "next_evidence": "Select the consumption brief, medical/galley allowances, water quality, packaging, storage losses and waste capacities. Installed inventories remain open."
    },
    {
      "step": "5. Common-fault requirements",
      "completed": "The fault matrix identifies required protection and the physical observations needed to show recovery. Network and shield availability cannot substitute for essential local functions.",
      "next_evidence": "Demonstrate electrical/gas/cooling segregation, local instrumentation, emergency transfer and independent recovery for the same vessel configuration."
    },
    {
      "step": "6. Unoccupied integration checks",
      "completed": "Software checks exercise missing data, zero inventory, insufficient removal rate, transient energy and peak-power shortfalls. They do not close physical tests.",
      "next_evidence": "Conduct controlled, authorized shore tests with no occupied exposure. Establish calibrated measurements, acceptance criteria and fault recovery before any occupied trial."
    },
    {
      "step": "7. Hull and independent acceptance",
      "completed": "Hull, depth, buoyancy, flooding, fire separation, escape and rescue remain explicit gates ahead of occupied operation.",
      "next_evidence": "Obtain vessel-specific naval architecture and life-support evidence. ZSA independently reviews hazards, test authorization and acceptance."
    }
  ],
  "fault_cases": [
    {
      "fault": "Common reactor/steam source lost",
      "required_response": "Treat propulsion and normal service generation as unavailable. Preserve essential local functions from the protected emergency paths.",
      "evidence": "Measured transfer continuity, essential-bus peak/energy budget, independent atmosphere provision and shutdown-cooling performance."
    },
    {
      "fault": "Normal feeder or Power Fuse Chamber fault",
      "required_response": "Isolate the fault without removing every protected emergency path.",
      "evidence": "Protection selectivity and physical segregation for the chosen fault location and fire/flood zones."
    },
    {
      "fault": "Main CO2-removal train unavailable",
      "required_response": "Use the separately protected emergency provision; preserve gas monitoring and conditioning.",
      "evidence": "Effective CO2 uptake and removal rate, gas distributions and breakthrough under the same occupied-load reference."
    },
    {
      "fault": "Main cooling path lost",
      "required_response": "Reduce or terminate the heat source locally and preserve required residual-heat and essential cabin cooling.",
      "evidence": "Measured heat loads, available sink, independent pumping/control supply and temperature response."
    },
    {
      "fault": "Fiber link lost or common sensor drift",
      "required_response": "Mark old reports as stale. Retain independent local indications and protection; compare an independent reference.",
      "evidence": "Correct timestamps and alarms, local operation during network loss, and a reference that does not share the same failure."
    },
    {
      "fault": "Flooding or loss of main electrical power",
      "required_response": "Retain local depth/trim indications and the established independent surfacing/recovery means.",
      "evidence": "Pressure-hull, displacement/trim, compartment and recovery analyses followed by authorized physical demonstration."
    }
  ],
  "power_budget": {
    "boundary": "Electrical loads are expressed at the service-generator terminals, including declared distribution losses. Charging is a separate generator-side input. Shaft output is measured at the two shafts together. Combined conversion efficiency relates heat entering the power cycle to these shaft and generator-terminal outputs.",
    "loads": [
      {
        "id": "air",
        "label": "Breathing-air package",
        "scope": "Circulation, CO2 removal, oxygen controls and air instruments. Include shared package fans once."
      },
      {
        "id": "cooling",
        "label": "Separate cooling duties",
        "scope": "Plant, cabin and essential shutdown cooling not already inside another package."
      },
      {
        "id": "controls",
        "label": "Local controls and instruments",
        "scope": "Protection, navigation and alarms outside the breathing-air package. Include supervisory electronics only where required."
      },
      {
        "id": "communications",
        "label": "Communications",
        "scope": "Normal links and independent emergency communications. Avoid duplication with local control electronics."
      },
      {
        "id": "recovery",
        "label": "Pumps and recovery services",
        "scope": "Continuous duty only. Peak demand and extra transient energy require the separate reserve inputs."
      },
      {
        "id": "hotel",
        "label": "Lighting, water and habitability",
        "scope": "Lighting, food storage, galley, water, sanitation and medical services. Identify what remains essential."
      },
      {
        "id": "optional",
        "label": "Research and optional loads",
        "scope": "Research and shield experiments. Declare zero emergency duty only when isolation and load shedding are supported."
      },
      {
        "id": "distribution",
        "label": "Distribution losses",
        "scope": "Conversion and feeder losses downstream of the service-generator terminals, excluding losses already counted in package figures."
      }
    ],
    "equations": [
      [
        "Normal service demand",
        "Sum the normal electrical load entries."
      ],
      [
        "Emergency continuous demand",
        "Sum the emergency entries. Peak power and transient energy remain separate."
      ],
      [
        "Required service-generator output",
        "Normal demand + generator-side charging input."
      ],
      [
        "Generator headroom",
        "Declared available generator output - required service-generator output."
      ],
      [
        "Useful cycle output",
        "Selected total shaft output + required service-generator output."
      ],
      [
        "Heat entering the cycle",
        "Useful cycle output / declared combined conversion efficiency."
      ],
      [
        "Cycle conversion heat",
        "Heat entering the cycle - useful cycle output."
      ]
    ],
    "scope": "This steady-state balance does not size machinery, determine a fuel or fusion reaction, establish a thermodynamic cycle, select steam conditions, predict speed, or calculate shutdown heat. Conversion heat requires allocation to real heat-removal paths; cabin loads, electrical dissipation and charging losses need their own thermal accounting. A separate turbine-generator shares the reactor, steam and cooling dependencies. Entry totals require a complete equipment inventory, not assumed capacities.",
    "consistency_review": [
      "Workbook v11, the public concept and the cutaway agree on 48 crew, 48 planned berths, three decks, one core, two propellers and 12,000 kW total shaft target.",
      "R5 oxygen/CO2 demand remains reference arithmetic. Food/water rates, installed air equipment, usable emergency capacity and all physical ratings remain open.",
      "The cutaway remains unscaled and its furnishings are representative. No hull dimension, compartment capacity or evacuation clearance is inferred from the picture.",
      "At the full shaft target for all 336 normal-mission hours, shaft work alone would be 4,032 MWh. This is a continuous-target reference, not a mission energy forecast."
    ]
  }
}