KETS Cycle
Zorak’s proposed Kinetic Energy Transfer System (KETS-1) routes surplus charged-particle energy to the stern drives through the electrical bus.
One boost on demand
One command starts recovery on wing A. Wing B joins at 10 seconds and returns to bypass at 170 seconds. Wing A returns to bypass at 180 seconds. The ordinary engines keep running as both wings cool. Another boost needs a fresh command and local clearance.
With a 65°C converter target, the 35°C inlet delivered more impulse than active chilling to 27.5°C in the example where the chiller moved six units of heat per unit of electricity. The model therefore keeps the 35°C inlet as its reference for an immediate boost.
An unrestricted reference run at a 35°C inlet gave the loaded 900,000-tonne flagship 1,828 N·s of extra forward impulse by 300 seconds, or 2.03 micrometres per second over the same engines in bypass. That run allowed the converters to reach 72.5°C.
Compare one boost with pre-cooling and recovery power included
Earlier three-minute pulse and cooling-fault replay
This earlier thermal study follows one 180-second pulse until each converter reaches the study’s cooldown threshold. Compare the nominal run with added converter heat or a loss of branch A’s spare cooling bank. The model assumes surplus particles and keeps fusion output at 213.19 MW.
Playback runs at 8× speed. Use the slider to inspect a single reading.
Pre-cool in bypass
- Net ship power
- Combined stern thrust
- Main-loop heat load
- Highest converter heat release
- Heat in fullest branch buffer
Steady bypass supplies 63.96 MW and 1,028.1 N with the KCS pumps off. The replay keeps the pumps running through cooldown, drawing 0.10 MW in total.
Simulated ship powerSteady bypass · 63.96 MW
-
Before 0 sPre-cool in bypass
Run both KCS loops. Verify coolant flow, radiator access, heat storage and a surplus that leaves plasma heating stable.
-
0–20 sRamp up A, then B
GENI starts A at 0 s and starts B at 10 s. Each branch rises to 5 MW of diversion.
-
20–160 sAssist propulsion
SERAT can send the net electrical gain to the drives after protected ship loads are met. AXIOM can end the pulse early.
-
160–180 sRamp down B, then A
B ramps down from 160 s and A from 170 s. Both are back in bypass by 180 s.
-
180 s onwardCool in bypass
Both pumps keep circulating after diversion ends. A repeat pulse requires measured temperatures, coolant flow, available storage and local clearance.
Zorak’s original 160-second propulsion trial
On 23 November 2026, the twin-drive simulation held fusion output at 213.19 MW with one main radiator sector unavailable. Both branches together diverted 10 MW for a 120-second full-power hold. They returned to bypass at 160 seconds.
- Combined thrust, bypass to full pulse
- 1,028 to 1,086 N
- Modeled thrust gain
- +5.65%
- Net bus power, bypass to full pulse
- 63.96 to 67.51 MW
The gain assumes the particles were surplus to plasma heating and includes both KCS pumps at full pulse. The modeled main-loop heat peaked at 186.62 MW against a 193.82 MW allowance. Neither external KCS buffer accumulated heat in the planned trial.
Replay the planned pulse and the cooling fault · Original 23 November trial report and plots
The Gen 2 power study evaluates a separate 99.91 MW net electrical target per wing. The thrust comparison applies to Zorak’s simulated stern drives. Physical thrust remains unverified.
Earlier speed projection at formation cruise
This 180-second comparison starts at the maximum sustained formation cruise target of 0.075c (22,484.43435 km/s). Both runs assume this speed is already attained and use the earlier twin-drive model’s cruise mass and exhaust assumptions. The 180-second onboard burn includes both ramps, with 140 seconds at full diversion.
| Forward burn | Departure-frame speed gained (mm/s) |
|---|---|
| After 180 s with KETS | 0.29528 |
| After 180 s in bypass | 0.28112 |
KETS adds 0.01416 mm/s beyond the matching burn in bypass, measured in the departure frame of Earth and the destination. The table shows the small increments separately from the starting cruise speed. The formation design threshold is above 20,000 km/s. This projection retains the pulse’s reference mass, power and exhaust assumptions. Physical flight qualification remains open.
How the current cruise reference is applied
The paired reference burns supply the local speed increments. For an onboard increment u at starting speed βc, relativistic velocity addition gives the departure-frame increment u(1 − β²)/(1 + βu/c). Both runs use the same starting cruise reference as the fleet movement display. Their difference is the additional KETS gain.
Earlier twin-drive benchmark and pulse assumptions
| Point in the earlier simulation | Departure-frame speed (km/h) | Speed gained in pulse (mm/s) |
|---|---|---|
| Start of both runs | 9,482.44641 | 0 |
| After 180 s with KETS | 9,482.44748 | 0.2969 |
| After 180 s in bypass | 9,482.44743 | 0.2827 |
The retained benchmark gives an additional 0.0142 mm/s over bypass.
The conventional-exhaust case uses a departure mass of 690,000 tonnes, including 69,000 tonnes of propellant, with equal speed changes for acceleration and braking. This gives a cruise mass of 654,591 tonnes. The two forward burns use that mass, an effective exhaust speed of 50 km/s and the same 213.19 MW of fusion output.
The model integrates thrust over the 180 seconds to calculate propellant use (3.8876 kg with KETS and 3.7012 kg in bypass). The ideal rocket equation converts each mass change to an increase from the starting cruise. Physical flight validation remains open.
Zorak’s conventional-exhaust study NASA Glenn · Ideal rocket equation OpenStax · Relativistic velocity transformation
Cooling and hold checks from the earlier replay
| Modeled case | Peak stored heat per buffer (MJ) | Decision and timing |
|---|---|---|
| Nominal pulse | 0.00 | Both branches in bypass at 180 s. Cooling marker at 190.8 s (10.8 s after bypass). |
| Added converter heat | 38.50 | Both branches in bypass at 180 s. Cooling marker at 208.0 s (28.0 s after bypass). 61.50 MJ remains free in the fullest buffer at its peak. |
| Branch A loses its spare radiator bank | 0.58 | A isolates at 60 s; its cooling marker is 75 s. B enters bypass at 170 s; its cooling marker is 180.8 s. |
| One crew cooling train in warm conditions | — | Hold before diversion. 1.235 MW available for a 1.330 MW crew load. |
| All diverted plasma heat needs replacing | — | Hold before diversion. Reheating draws 12.50 MW. Net bus power falls 8.95 MW below bypass. |
Times are measured aboard Zorak from the first diversion. The time after bypass is the remaining cooling interval. A zero buffer peak means no stored-heat accumulation while the radiators reject heat. A dash marks a held case whose pulse was not simulated.
At full transfer each branch diverts 5 MW. The stress run adds 0.30 MW at each converter from 40 to 180 s. Both converters use a 5-second heat response. The model marks cooldown once both buffers are empty and each converter releases at most 0.075 MW of residual heat. At nominal peak the main loop carries 186.62 MW of its 258.42 MW dispatch allowance.
At cutoff the ship keeps its forward velocity. In the current-cruise projection, reverse propulsion must cancel the full modeled forward increment of 0.29528 mm/s in the departure frame to return to the starting 0.075c (22,484.43435 km/s). This restores the starting cruise speed. Stopping the vessel requires a separate full braking profile.
Earlier reverse-pulse benchmark
In the conventional twin-drive case, once reverse thrust is aligned, 189.1 s at 1,028.1 N consumes 3.888 kg and cancels the full 0.2969 mm/s forward increment, returning to 9,482.44641 km/h. This ideal handoff assumes constant reverse thrust and excludes time and propellant for turning.
Neutrons deposit heat in surrounding structures. The thermal generator uses that heat to make electricity in both bypass and recovery.
Charged helium nuclei help heat the plasma. During a pulse, KETS converts only the available surplus to conditioned DC electricity.
Both paths feed the core’s protected electrical lane.
- Local Fuse A or B
- Central fuse and matching SERAT trunk
- Independent MAGTRANS assemblies in R16.9.1. The numerical pulse uses the earlier twin-drive reference.
- Expelled propellant produces thrust
- Coolant picks up converter heat
- Buffer stores excess heat
- Radiators reject heat to space
- Cooled fluid returns to the converter
Each KETS branch has its own KCS path. SERAT’s main radiator loop handles the main plant and drives.
Earlier 5 MW steady-state comparison before KCS pump demand
At 213.19 MW of fusion output, the recovery branch sends 3.325 MW to SERAT. The net gain before KCS pump demand is 1.825 MW after displaced thermal generation. Replacing all 5 MW as plasma heat uses 6.25 MW of electrical input.
193.82 MW available for main-loop dispatch. This steady-state comparison uses the shared R4 cooling budget with one sector out. Zorak’s three-minute simulation gives each KETS branch a separate KCS path and includes its pump demand.
| Quantity | KETS bypassed | Surplus particles | Plasma heat replaced |
|---|---|---|---|
| Electricity to both stern drives (MW) | 42.84 | 44.08 | 39.82 |
| Combined thrust (N) | 1,028.1 | 1,058.0 | 955.7 |
| Heat to main radiators (MW) | 186.36 | 185.62 | 188.17 |
See Zorak’s three-minute result Compare the KETS fleet configurations See the R4 cooling rating ITER Engineering Basis Handbook · volume 1, chapter 4, alpha particles and plasma heating