Qi Fleet cabin air cycle
Follow the air the crew breathes through an Anorak-based cutaway. Trace the return ducts, see how the ship removes carbon dioxide and adds oxygen, then isolate a compromised zone.
Normal operation / Fault response / Recovery Interactive replay
Starting conditions
The Anorak-based cutaway starts with occupied zones and a working air revitalization path.
Operating sequence
Collect cabin air
Fans draw air back from occupied zones. Local sensors track oxygen partial pressure, carbon dioxide, cabin pressure, humidity, temperature and contaminants. NEXUS compares readings across zones and flags uncertain data.
Filter and scrub
Particle filters catch dust and aerosols. Trace-gas treatment and regenerable scrubbers remove contaminants and crew-exhaled carbon dioxide. The scrubbers send captured CO₂ to separate handling.
Recover water and heat
A cooling coil condenses moisture from the return air. The condensate goes to water treatment and quality checks. A sealed exchanger transfers cabin heat to SERAT while keeping cabin air and coolant in separate circuits. The plant adjusts humidity and supply temperature as needed.
Replenish breathable gas
In the fleet concept, a powered electrolyser can split verified water into oxygen and hydrogen. Oxygen enters the treated-air supply through a controlled feed. Hydrogen goes to a separate handling path. Stored oxygen provides backup, and a separate buffer-gas reserve supports pressure recovery after a leak is isolated.
Distribute and verify
Zone air-handling units recirculate treated air through habitation, command, and other occupied spaces. Anorak’s concept includes separate clean airflow for research and controlled ventilation for medical isolation and airlocks. Local instruments verify conditions before a zone returns air to the shared loop.
Isolate and restore
Local protection closes the laboratory’s supply and return. In this example, essential power keeps air circulating through the intact refuge, where stored oxygen is available as needed. Verify the fault is cleared and air quality and pressure are stable before reconnecting the laboratory.
Hold and recovery
Isolate a compromised zone in the model and verify stable pressure and air quality before reconnecting its circulation.
Model and references
Open the interactive cycleThis conceptual cutaway follows Anorak’s earlier atmosphere-management layout. NEXUS supervises, local protection can isolate a zone, and AXIOM retains final physical authority. ZSA qualifies the design. Airflow, gas inventories, electrical draw and endurance require vessel-specific verification.
ZENIT concept procedure. Models and replays use illustrative conditions.