Skip to Operations
EARTH & SPACE / PROGRAM ATLAS
← Operations catalogue

Space Qi Vanguard Fleet

Qi Fleet water cycle and crew shielding

The Integrated Hull Water Matrix (IHWM) routes shield water through Loop C to segmented cells around occupied areas. The retained water provides passive shielding.

Normal operation / Fault response / Recovery Interactive replay

Starting conditions

Recovered water qualifies for the dedicated Loop C circuit. Its shielding cells and isolation points are identified by zone.

Operating sequence

  1. Recover and verify water

    Eligible wastewater and condensate pass through the vessel’s treatment and verification stages. Approved make-up water can enter the isolated Loop C filling interface.

  2. Charge the Loop C reserve

    The dedicated reserve supplies Loop C through its own manifold. Potable, hygiene, reactor cooling and emergency cooling circuits have separate fluid paths.

  3. Fill the shielding cells

    Protected branches fill segmented cells within the hull envelope around crew spaces and the assigned storm refuge. Water Control Center tracks fill and available reserve by zone.

  4. Retain water and circulate

    Water mass along exposure paths provides the shielding. Normal circulation can condition the water or equalize temperature. Filled, isolated cells retain their water during a pump or power loss.

  5. Isolate a damaged branch

    Local valves isolate a leak and retain water in the other cells. Collect suspect water in a sealed holding tank and flag the affected zone’s coverage for reassessment.

  6. Verify coverage and restore

    Confirm cell integrity, retained fill and exposure paths before returning a zone to the available refuge list. NEXUS supervises, AXIOM can hold operation, and ZSA owns qualification.

Section through a crew refuge with segmented water cells inside the hull, alongside a flow diagram of intact and isolated branches and a separate SERAT heat exchanger.
Supply and return valves can isolate a damaged branch while other cells retain water. The exchanger transfers heat across a boundary between the Loop C and SERAT fluids.

Hold and recovery

After a leak or fill discrepancy, verify retained water and coverage before listing the affected zone as an available refuge.

Model and references

Open the interactive cycle

Crew dose and the required water depth depend on the vessel layout, the retained fill and the radiation environment. The vessel fits are design models with dose qualification pending.

ZENIT concept procedure. Models and replays use illustrative conditions.